1. Safety Precautions
(l)
WARNING
When cleaning the instrument and cleaning inside of the reagent bottle rack, be careful
not to assume an unnatural, semi-crouching posture.
If you maintain an unnatural, semi-crouching posture, you may hurt your lower back.
Do not touch a retort, paraffin oven or paraffin container with bare hands while it is
heated.
Injury or burns may result. Wear protective gears and heat-resistant gloves.
Do not place a paraffin container on the paraffin oven door while the door is open.
The paraffin container may drop, resulting in injury.
Secure the instrument with seismic anchorage (optional) to prevent it from
moving/falling in case of earthquake.
Provide fall prevention measure to prevent the instrument from moving should a disaster occur.
When opening the retort lid, make sure the “Ambient” indication.
If the lid is opened while the retort is still under pressure, injury may occur. If the indication does not return
to "Ambient," do not forcibly open the retort lid, but contact the Sakura Finetek Technical Support
representative or local representative.
Do not apply strong impact on the glass doors.
It may cause shattered glass, resulting in injury.
Do not apply excessive force on the display.
The display may break and cause injury.
Do not remove the warning/caution labels.
Without these labels, the operators cannot be reminded of the necessary warning/cautionary information in
the day-to-day handling of the instrument, which may result in unexpected problems.
Do not put reagent, etc., on the instrument. Also, do not spill reagent on the painted
surfaces, caution/warning labels or touch screen.
If reagent spills over the instrument, the instrument may fail or sustain damage.
Use the activated carbon filters even when the instrument is connected to an external
exhaust device.
The instrument has been designed by assuming that the activated carbon filters will be installed, so
abnormality may occur if the filters are not installed. If the instrument is connected to an external exhaust
device, the activated carbon filters need not be replaced.
Replace the activated carbon filters in the fume control unit periodically.
The activated carbon filters are provided as a precautionary measure to minimize any harmful vapor that
may be released to around the instrument. Expired activated carbon filters cannot maintain exhaust gas at
an appropriate level of concentration. Also, the work room must be ventilated.
Replace the retort lid gasket periodically.
Otherwise, the sealing property of the gasket may drop and a fill error may occur.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sakura Histo-Tek VP1 and is the answer not in the manual?

Sakura Histo-Tek VP1 Specifications

General IconGeneral
BrandSakura
ModelHisto-Tek VP1
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals