-28-
Mechanical Disassembly
3-5 AMC unit disassembly-5
1 Remove 8 screws-A (T3x8) to remove the mesh filter.
2 Remove 1 screw-B (T3x8) and press and slide the flat cable cover in the arrow direc-
tion as shown in the figure.
3 Remove each 2 screws-C (T3x8),2 screws-D (T3x12) to remove the base link unit,
sensor switch and AMC socket.
Mesh filter
AMC socket
Base link unit
Flat cable cover
Sensor
switch
Sensor
switch
Sensor
switch
Sensor
switch
Flat Cable
Put the wires through the
grooves. Not to pinch the wires
with the cover.
A
A
A
A
A
A
A
A
B
C
C
D
D
Flat cable