VC 1100 List of Setup Parameters
VC1100E/paralist Version 2 →
© Schenck VIBRO GmbH, D-64273 Darmstadt, Juni 98 C01 / C02 - C11 / C12 5-7
I 05 Sensitivity
Range : 0.8 ... 3750
Resolution : 0.8 ... 0.999
1.00 ... 9.99
10.0 ... 99.9
100 ... 3750
Function : Pickup sensitivity
I05 defines the pickup sensitivity for channel A and B.
VIBROCONTROL 1100 accepts sensitivities within the ranges li-
sted in the following table:
Pickup type Unit min. value max. value
Accelerometer mV/g 8.0 120
(I03 = a) mV/m/s
2
0.8 12
Vibration Velocity mV/mm/s 15 150
(I03 = v) mV/ips 375 3750
I 06 Frequency response linearization
Choises : Y, N
Function : Y = Yes Frequency response linearization is
active
N = No Frequency response linearization is
not active
At a switch-on of the frequency response linearization, the
Schenck vibration velocity pickup supplies an exact measurement
even in low frequency ranges, e.g. measurements below the natu-
ral frequency of the pickup(f
0
< 8 Hz or f
0
< 15 Hz according to the
pickup type).
The standard equipment of the VIBROCONTROL 1100 system
comprises a frequency response linearization for transducer natu-
ral frequencies of f
0
= 8 Hz. The special design for f
0
= 15 Hz is
identified by the adhesive label „moving coil linearization 15 Hz"
which is located on the right side of the printed circuit cover
underneath the grounding bar, after opening the lid.