VC 1100 List of Setup Parameters
VC1100E/paralist Version 2
© Schenck VIBRO GmbH, D-64273 Darmstadt, Juni 98 C01 / C02 - C11 / C12 5-11
J 01 Channel A : Vibration
Choises : Y, N
Function : Enable or disable signal processing for channel A
Y = Yes Channel A processes the vibration
signal
N = No Channel A does not processes the
vibration signal
J 02 Channel B : Vibration
Choises : Y, N
Function : Enable or disable signal processing for channel B
Y = Yes Channel B processes the vibration
signal
N = o Channel B does not processes the
vibration signal
J 03 Channel A : Measured Parameter:
Choises : a, v, s
Function : Define the measured vibration parameter for
channel A
a = Vibration acceleration
v = Vibration velocity
s = Vibration displacement
J 04 Channel B : Measured Parameter
Choises : a, v, s
Function : Define the measured vibration parameter for
channel B
a = Vibration acceleration
v = Vibration velocity
s = Vibration displacement