EasyManua.ls Logo

SEW-Eurodrive MOVIDRIVE MDA90A-0640-503-X-S00

SEW-Eurodrive MOVIDRIVE MDA90A-0640-503-X-S00
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
Safety notes
Startup/operation
Operating Instructions – MOVIDRIVE
®
modular
18
2.10 Startup/operation
Observe the safety notes in the chapters "Startup" and "Operation" in the documenta-
tion.
Make sure that the present transport protection is removed.
Do not deactivate monitoring and protection devices of the machine or system even
for a test run.
Make sure the connection boxes are closed and screwed before connecting the sup-
ply voltage.
Depending on the degree of protection, products may have live, uninsulated, and
sometimes moving or rotating parts, as well as hot surfaces during operation.
Additional preventive measures may be required for applications with increased haz-
ard potential. You have to check the protection devices after each modification.
When in doubt, switch off the product whenever changes occur in relation to normal
operation. Possible changes are e.g. increased temperatures, noise, or oscillation. De-
termine the cause. Contact SEW‑EURODRIVE if necessary.
When the device is switched on, dangerous voltages are present at all power connec-
tions as well as at any connected cables and terminals. This also applies even when
the product is inhibited and the motor is at standstill.
Do not separate the connection to the product during operation.
This may result in dangerous electric arcs damaging the product.
If you disconnect the product from the voltage supply, do not touch any live compon-
ents or power connections because capacitors might still be charged. Observe the fol-
lowing minimum switch-off time:
10 minutes.
Observe the corresponding information signs on the product.
The fact that the operation LED and other display elements are no longer illuminated
does not indicate that the product has been disconnected from the supply system and
no longer carries any voltage.
Mechanical blocking or internal safety functions of the product can cause a motor
standstill. Eliminating the cause of the problem or performing a reset may result in the
drive re-starting automatically. If, for safety reasons, this is not permitted for the drive-
controlled machine, first disconnect the product from the supply system and then start
troubleshooting.
Risk of burns: The surface temperature of the product can exceed 60°C during opera-
tion.
Do not touch the product during operation.
Let the product cool down before touching it.
2.10.1 Energy storage unit
Products with a connected energy storage unit are not necessarily de-energized when
they have been disconnected from the supply system. Usually, the energy storage unit
stores sufficient energy to continue operation of the connected motors for a limited
period of time. It is not sufficient to observe a minimum switch-off time.
Perform a shutdown as described in the documentation in chapter "Service" > "Shut-
down".
24748536/EN – 11/2017