8 CONFIGURING THE CONNECTION SETTINGS
8027311 / V1-0/2022-04|SICK
OPERATING INSTRUCTIONS|TDC-E (Telematic Data Collector)
Subject to change without notice
8.2.4 Digital inputs and outputs
▸
Open the DIO connection parameter via the gear icon.
▸
Activate digital inputs and outputs via the Enabled checkbox.
▸
Save activation and reopen parameters.
▸
Configure used interfaces DIO_A to DIO_F as digital inputs and outputs.
▸
If necessary, configure additional digital inputs and outputs.
▸
Save configuration with Save & Close.
DioDirectionChange
WebSocket server URL
ws://192.168.0.100:31768/ws/tdce/dio/direction
MQTT subscription directory
tdce/dio/direction
Results
{
"Name":"DIO_A",
"Direction":"Output"
}
API
DIO