8 CONFIGURING THE CONNECTION SETTINGS
72
8027311 / V1-0/2022-04|SICK
OPERATING INSTRUCTIONS|TDC-E (Telematic Data Collector)
Subject to change without notice
8.2.4 Digital inputs and outputs
Open the DIO connection parameter via the gear icon.
Activate digital inputs and outputs via the Enabled checkbox.
Save activation and reopen parameters.
Configure used interfaces DIO_A to DIO_F as digital inputs and outputs.
If necessary, configure additional digital inputs and outputs.
Save configuration with Save & Close.
DioDirectionChange
WebSocket server URL
ws://192.168.0.100:31768/ws/tdce/dio/direction
MQTT subscription directory
tdce/dio/direction
Results
{
"Name":"DIO_A",
"Direction":"Output"
}
API