Parameter list 05.05
11-108 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU
Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U126
(2126)
*
S00
(B125)
Operands for 7
th
adder / subtracter (result = K9126) FB 26
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U127
(2127)
*
S00
(B125)
Operands for 8
th
adder / subtracter (result = K9127) FB 27
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U128
(2128)
*
S00
(B125)
Operands for 9
th
adder / subtracter (result = K9128) FB 28
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U129
(2129)
*
S00
(B125)
Operands for 10
th
adder / subtracter (result = K9129) FB 29
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U130
(2130)
*
S00
(B125)
Operands for 11
th
adder / subtracter (result = K9130) FB 30
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U131
(2131)
*
S00
(B125)
Operands for 12
th
adder / subtracter (result = K9131) FB 31
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Adders / subtracters for double word connectors
The 3 operands of a function block are selected in each case via the three indices of a parameter.
The result is switched to a double word connector and a connector.
The double word connector is limited to between -200.00 and +199.99%.
The connector is limited to between –0.003052 and +0.003052% (= value range of LOW word of a double word connector
=
±200% / 65536)
U132
(2132)
*
S00
(B151)
Operands for 1
st
adder / subtracter FB 48
Operands for 2
nd
adder / subtracter FB 49
[SW 1.9 and later]
1
st
adder / subtracter: result = KK9490 and K9491
2
nd
adder / subtracter: result = KK9492 and K9493
i001: Addition value for 1
st
adder/subtracter
i002: Addition value for 1
st
adder/subtracter
i003: Subtraction value for 1
st
adder/subtracter
i004: Addition value for 2
nd
adder/subtracter
i005: Addition value for 2
nd
adder/subtracter
i006: Subtraction value for 2
nd
adder/subtracter
Settings:
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 6
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
Sign inverters
The contents of the connector selected in the parameter are negated (two's complement). The result is applied to the specified connector.
U135
(2135)
*
S00
(B125)
Source for 1
st
sign inverter (result = K9135) FB 35
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U136
(2136)
*
S00
(B125)
Source for 2
nd
sign inverter (result = K9136) FB 36
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U137
(2137)
*
S00
(B125)
Source for 3
rd
sign inverter (result = K9137) FB 37
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline