05.05 Parameter list
SIEMENS AG 6RX1700-0AD76 11-135
SIMOREG DC Master Operating Instructions
PNU
Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U387
(2387)
*
S00
(B207)
Source for input signal, inverter 8 (output = B9457) FB 187
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U388
(2388)
*
S00
(B207)
Source for input signal, inverter 9 (output = B9458) FB 188
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U389
(2389)
*
S00
(B207)
Source for input signal, inverter 10 (output = B9459) FB 189
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U390
(2390)
*
S00
(B207)
Source for input signal, inverter 11 (output = B9460) FB 190
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U391
(2391)
*
S00
(B207)
Source for input signal, inverter 12 (output = B9461) FB 191
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U392
(2392)
*
S00
(B207)
Source for input signal, inverter 13 (output = B9462) FB 192
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U393
(2393)
*
S00
(B207)
Source for input signal, inverter 14 (output = B9463) FB 193
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U394
(2394)
*
S00
(B207)
Source for input signal, inverter 15 (output = B9464) FB 194
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U395
(2395)
*
S00
(B207)
Source for input signal, inverter 16 (output = B9465) FB 195
As for U380
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
NAND elements with 3 inputs each
The input signals selected via the 3 indices of the parameter are combined in an NAND operation and the result applied to the specified
binector.
U400
(2400)
*
S00
(B207)
Source for input signals, NAND element 1 (output = B9470) FB 200
i001 Source for input 1
i002 Source for input 2
i003 Source for input 3
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U401
(2401)
*
S00
(B207)
Source for input signals, NAND element 2 (output = B9471) FB 201
As for U400
All binector numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U402
(2402)
*
S00
(B207)
Source for input signals, NAND element 3 (output = B9472) FB 202
As for U400
All binector numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline

Table of Contents