11818 Energy, Conditional Real Out WH
3-Phase total accumulated conditional real energy out
of the load
11820
Energy, Conditional Reactive
Out
VArH
3-Phase total accumulated conditional reactive energy
out of the load
11822 Energy, Conditional Apparent VAH
3-Phase total accumulated conditional apparent
energy
11824
Energy, Incremental Real In,
Last Complete Interval
WH
3-Phase total accumulated incremental real energy
into the load
11826
Energy. Incremental Reactive
In, Last Complete Interval
VArH
3-Phase total accumulated incremental reactive
energy into the load
11828
Energy, Incremental Real
Out, Last Complete Interval
WH
3-Phase total accumulated incremental real energy
out of the load
11830
Energy, Incremental Reactive
Out, Last Complete Interval
VArH
3-Phase total accumulated incremental reactive
energy out of the load
11832
Energy, Incremental
Apparent, Last Complete
Interval
VAH
3-Phase total accumulated incremental apparent
energy
11836
Energy, Incremental Real In,
Present Interval
WH
3-Phase total accumulated incremental real energy
into the load
11838
Energy. Incremental Reactive
In, Present Interval
VArH
3-Phase total accumulated incremental reactive
energy into the load
11840
Energy, Incremental Real
Out, Present Interval
WH
3-Phase total accumulated incremental real energy
out of the load
11842
Energy, Incremental Reactive
Out, Present Interval
VArH
3-Phase total accumulated incremental reactive
energy out of the load
11844
Energy, Incremental
Apparent, Present Interval
VAH
3-Phase total accumulated incremental apparent
energy
11846 Energy, Reactive, Quadrant 1 VArH
3-Phase total accumulated incremental reactive
energy – quadrant 1
11848 Energy, Reactive, Quadrant 2 VArH
3-Phase total accumulated incremental reactive
energy – quadrant 2
11850 Energy, Reactive, Quadrant 3 VArH
3-Phase total accumulated incremental reactive
energy – quadrant 3
11852 Energy, Reactive, Quadrant 4 VArH
3-Phase total accumulated incremental reactive
energy – quadrant 4
11854
Cumulative Usage
Input Channel #1
(2)
The user must identify the units to be used in the
accumulation.
11856
Cumulative Usage
Input Channel #2
(2)
The user must identify the units to be used in the
accumulation.
11858
Cumulative Usage
Input Channel #3
(2)
The user must identify the units to be used in the
accumulation.
11860
Cumulative Usage
Input Channel #4
(2)
The user must identify the units to be used in the
accumulation.
11862
Cumulative Usage
Input Channel #5
(2)
The user must identify the units to be used in the
accumulation.
11864
Energy, Real 3-Phase Total
Usage Today
WH
11866
Energy, Real 3-Phase Total
Usage Yesterday
WH
Table A–7: Abbreviated Floating-Point Register List
Reg Name Units Notes