EasyManua.ls Logo

Siemens SIMATIC ET 200pro - Page 7

Siemens SIMATIC ET 200pro
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table of contents
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 04/2015, FW V4.7.3, A5E34257324B AB
7
8.4 Setpoint calculation ............................................................................................................... 107
8.4.1 Overview of setpoint processing ........................................................................................... 107
8.4.2 Invert setpoint ....................................................................................................................... 108
8.4.3 Inhibit direction of rotation ..................................................................................................... 108
8.4.4 Skip frequency bands and minimum speed .......................................................................... 109
8.4.5 Speed limitation .................................................................................................................... 110
8.4.6 Ramp-function generator ...................................................................................................... 110
8.5 Motor control ......................................................................................................................... 115
8.5.1 V/f control .............................................................................................................................. 115
8.5.1.1 Characteristics of U/f control ................................................................................................. 116
8.5.1.2 Selecting the U/f characteristic ............................................................................................. 117
8.5.1.3 Optimizing motor starting ...................................................................................................... 118
8.5.2 Vector control ........................................................................................................................ 120
8.5.2.1 Overview ............................................................................................................................... 120
8.5.2.2 Select motor control .............................................................................................................. 121
8.5.2.3 Optimizing the speed controller ............................................................................................ 122
8.5.2.4 Friction characteristic ............................................................................................................ 124
8.5.2.5 Moment of inertia estimator .................................................................................................. 126
8.6 Protection and monitoring functions ..................................................................................... 132
8.6.1 Inverter temperature monitoring ........................................................................................... 132
8.6.2 Monitor the motor temperature via a temperature sensor .................................................... 135
8.6.3 Protecting the motor by calculating the motor temperature .................................................. 138
8.6.4 Overcurrent protection .......................................................................................................... 139
8.7 Application-specific functions ................................................................................................ 140
8.7.1 Functions that match the application .................................................................................... 140
8.7.2 Unit changeover .................................................................................................................... 141
8.7.2.1 Changing over the motor standard ....................................................................................... 142
8.7.2.2 Changing over the unit system ............................................................................................. 142
8.7.2.3 Changing over process variables for the technology controller ............................................ 143
8.7.2.4 Switching units with STARTER ............................................................................................. 143
8.7.3 Braking the motor electrically ................................................................................................ 145
8.7.3.1 DC braking ............................................................................................................................ 145
8.7.3.2 Braking with regenerative feedback to the line ..................................................................... 148
8.7.4 Motor holding brake .............................................................................................................. 148
8.8 Safe Torque Off (STO) safety function ................................................................................. 153
8.8.1 Description of functions......................................................................................................... 153
8.8.2
Prerequisite for STO use ...................................................................................................... 156
8.8.3 Commissioning STO ............................................................................................................. 156
8.8.3.1 Commissioning tool ............................................................................................................... 156
8.8.3.2 Protection of the settings from unauthorized changes ......................................................... 157
8.8.3.3 Changing settings ................................................................................................................. 157
8.8.3.4 Interconnecting the "STO active" signal ............................................................................... 158
8.8.3.5 Setting the STO input signal ................................................................................................. 159
8.8.3.6 Setting the forced checking procedure (test stop) ................................................................ 160
8.8.3.7 Activate settings .................................................................................................................... 161
8.8.3.8 Approval - completing commissioning .................................................................................. 162
8.9 Switchover between different settings .................................................................................. 166

Table of Contents

Other manuals for Siemens SIMATIC ET 200pro

Related product manuals