New properties/functions
Distributed I/O system
System Manual, 09/2019, A5E03576849-AJ
15
What's new?
What are the customer benefits?
Where can I find information?
GetSMCinfo instruction With the help of the GetSMCinfo instruction
you can respond to information provided by
the memory card in the user program and if
required, replace the memory card as a pre-
cautionary measure. This makes sense in
particular if you write to the card often in your
application, for example if you use data logs.
Section AUTOHOTSPOT
Testing with breakpoints When testing with breakpoints, you execute a
program from one breakpoint to another.
Testing with breakpoints provides you with
the following advantages:
Testing SCL and STL program code with
the help of breakpoints
Localization of logic errors step by step
Simple and quick analysis of complex
programs prior to actual commissioning
Recording of current values within individ-
ual executed loops
Use of breakpoints for program validation
also possible in SCL/STL networks within
LAD/FBD blocks
Section Test functions
(Page 258)
Changed
contents
Reading out the identification
and maintenance data using
the Get_IM_Data instruction
With the Get_IM_Data instruction you can
read out the identification and maintenance
data of the modules without much program-
ming work.
With the Get_IM_Data instruction, you can
access the identification and maintenance
data (I&M) of a module in the user program.
I&M data is information saved in a module.
This allows you to
check the system configurations
react to hardware changes
react to hardware faults in the user pro-
gram.
Finding and elimination of hardware errors is
made easier.
Section Reading out and enter-
ing I&M data (Page 226)
Time synchronization For all applications that need the exact time,
you update the CPU time using the NTP
process. This also automatically sets the
CPU time beyond subnet limits.
Section Time synchronization
(Page 220)
Firmware update via acces-
sible devices
You are given information on fast firmware
updates via accessible devices in the net-
work.
Section Firmware update
(Page 242)

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C