Protection
9.5 Copy protection
Distributed I/O system
System Manual, 09/2019, A5E03576849-AJ
165
4. Activate the option "Serial number is inserted when downloading to a device or a memory
card" if the serial number is to be inserted automatically during the uploading process
(dynamic binding). Assign a password using the "Define password" button to link the use
of a block additionally to the input of a password.
Activate the option "Enter serial number" if you want to manually bind the serial number of
the CPU or the SIMATIC memory card to a block (static binding).
5. You can now set up the know-how protection for the block in the "Know-how protection"
area.
Note
If you download a copy
-protected block to a device that does not match the specified
serial number, the entire down
load operation will be rejected. This means that blocks
without cop
y protection will also not be downloaded.
Removing copy protection
To remove copy protection, follow these steps:
1. Remove any existing know-how protection.
2. Open the properties of the block in question.
3. Select the "Protection" option under "General".
4. In the "Copy protection" area, select the "No binding" entry from the drop-down list.
Figure 9-9 Removing copy protection

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C

Related product manuals