SIMATIC memory card
11.2 Setting the card type
S7-1500 Automation System
System Manual, 01/2013, A5E03461182-01
139
11.2 Setting the card type
Setting the card type
You can use the SIMATIC memory card as a program card or as a firmware update card.
To set the card type, insert the SIMATIC memory card in the programming device's card
reader, and select the "SIMATIC Card Reader" folder in the project tree.
In the properties of the selected SIMATIC memory card, specify the card type:
Program card
You use a program card as an external load memory for the CPU. It contains the entire
user program for the CPU. The user program is transferred from the load memory to the
work memory and runs there. If the SIMATIC memory card with the user program is
removed, the CPU goes into STOP mode.
The following folder is created on the SIMATIC memory card: SIMATIC.S7
Firmware update card
Firmware for the CPU, for a display and for I/O modules can be stored on a SIMATIC
memory card. It is thus possible to perform a firmware update with the help of a
specifically prepared SIMATIC memory card.
The following folder is created on the SIMATIC memory card: FWUPDATE.S7S
Reference
You can find additional information in the STEP 7 online help.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-1500 Automation System and is the answer not in the manual?

Siemens SIMATIC S7-1500 Automation System Specifications

General IconGeneral
SeriesSIMATIC S7-1500
ProgrammingTIA Portal (Totally Integrated Automation Portal)
Protection ClassIP20
CPUVarious models available (e.g., CPU 1511-1 PN, CPU 1518-4 PN/DP)
Controller TypeModular Controller
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Communication InterfacesPROFINET, PROFIBUS, Ethernet, OPC UA
Digital InputsVaries by model and expansion modules
Digital OutputsVaries by model and expansion modules
Analog InputsVaries by model and expansion modules
Analog OutputsVaries by model and expansion modules
Backplane BusHigh-speed backplane bus for fast communication between modules
RedundancySupported with specific models and configurations
SafetyIntegrated safety functions available
ScalabilityHighly scalable with modular expansion
Operating Temperature0°C to 60°C