EasyManuals Logo

Siemens SIMATIC S7-1500 Automation System User Manual

Siemens SIMATIC S7-1500 Automation System
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #140 background imageLoading...
Page #140 background image
SIMATIC memory card
11.3 Data transfer with SIMATIC memory cards
S7-1500 Automation System
140 System Manual, 01/2013, A5E03461182-01
11.3 Data transfer with SIMATIC memory cards
Transferring objects from the project to a SIMATIC memory card
When the SIMATIC memory card is inserted into the programming device or into an external
card reader, you can transfer objects as follows from the project tree (STEP 7) to the
SIMATIC memory card:
Individual blocks (multiple selection possible)
In this case a consistent transfer is available, i.e. the dependencies between blocks due
to block calls are taken into account.
CPU folder
In this case, all runtime-relevant objects including blocks and the hardware configuration
are transferred onto the SIMATIC memory card - just as when downloading.
To perform a transfer, you can transfer the objects by dragging and dropping, or use the
"Card Reader/USB memory > Write to memory card" command in the "Project" menu.
Firmware update via SIMATIC memory card
You can find information on how to perform a firmware update via SIMATIC memory card in
the Firmware update (Page 122) section.
Reference
For additional information about the SIMATIC memory card, refer to the STEP 7 online help.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-1500 Automation System and is the answer not in the manual?

Siemens SIMATIC S7-1500 Automation System Specifications

General IconGeneral
SeriesSIMATIC S7-1500
ProgrammingTIA Portal (Totally Integrated Automation Portal)
Protection ClassIP20
CPUVarious models available (e.g., CPU 1511-1 PN, CPU 1518-4 PN/DP)
Controller TypeModular Controller
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Communication InterfacesPROFINET, PROFIBUS, Ethernet, OPC UA
Digital InputsVaries by model and expansion modules
Digital OutputsVaries by model and expansion modules
Analog InputsVaries by model and expansion modules
Analog OutputsVaries by model and expansion modules
Backplane BusHigh-speed backplane bus for fast communication between modules
RedundancySupported with specific models and configurations
SafetyIntegrated safety functions available
ScalabilityHighly scalable with modular expansion
Operating Temperature0°C to 60°C