The Web server (WBM)
6.10 Logging
TIM 1531 IRC
280 Operating Instructions, 02/2018, C79000-G8976-C468-02
Options:
Ethernet Interface X1 / X2 / X3
Enable the interfaces for which you want to record data.
Data volume (kB)
Via the input box, you specify the overall size of the logging file.
Maximum file size: 10000 kB
Recording acc. to time
If the option is enabled, the recording is made for a configurable time.
Via the input box, you specify the recording time in seconds.
Max. recording duration: 600 s
Recording acc. to frames
If the option is enabled, the recording is made for a configurable number of frames.
Via the input box, you specify the number of frames.
Max. number of frames: 500 s
Start
With this button you start the logging.
Stop
With this button you stop the logging.