153
SJ12 E, SJ16 E, SJ20 E
241914ACA
Display Module Section 5 – Procedures
5.7-8 Set the Region
1. Make sure the display shows the main page.
2. Change the ACCESS LEVEL to level 1 (see 57-
5 Set the Access Level)
3. Press the UP or DOWN buttons to nd the
REGION menu, then press the MIDDLE button
to select it.
4. Press the UP or DOWN buttons to nd the
desired region. Press the MIDDLE button to
select it.
5. The display asks if you are sure. Press the LEFT
button to say NO and exit without the change.
Press the MIDDLE button to say YES and save
the change.
6. If you said YES, the display shows “SAVING
PARAMETER. WAIT PLEASE.” Do not cycle
power to the machine while waiting.
7. Cycle power to the ZAPI display to restore
ACCESS LEVEL 3 for normal daily operation.
5.7-9 Set the Battery Type
1. Make sure the display shows the main page.
2. Change the ACCESS LEVEL to level 1 (see 57-
5 Set the Access Level)
3. Press the UP or DOWN buttons to nd the
REGION menu, then press the MIDDLE button
to select it.
4. Press the UP or DOWN buttons to nd the
desired battery type. Press the MIDDLE button
to select it.
5. The display asks if you are sure. Press the LEFT
button to say NO and exit without the change.
Press the MIDDLE button to say YES and save
the change.
6. If you said YES, the display shows “SAVING
PARAMETER. WAIT PLEASE.” Do not cycle
power to the machine while waiting.
7. Cycle power to the ZAPI display to restore
ACCESS LEVEL 3 for normal daily operation.
5.7-10 Select the Console
1. Make sure the display shows the main page.
2. Change the ACCESS LEVEL to level 1 (see 57-
5 Set the Access Level)
3. Press the UP or DOWN buttons to nd the
CONSOLE menu, then press the MIDDLE
button to select it.
4. The display shows “CONNECTING TO...”
5. Press the UP or DOWN buttons to nd the
module you wish to connect to, then press the
MIDDLE button to select it.
▪
DISP EDZ S3x.xx - You can modify the display
parameters depending on the access level.
▪
AXMR2B 2GS3x.xx - You can modify the
inverter parameters depending on the access
level.
▪
AXSR2B 2GS3x.xx - You can monitor the
alarms. You cannot modify parameters in this
menu.