Somat eDAQ
lite
42
I2773-4.4 en
For more information on setting up a network node, see “Adding a Network Node” on
page 59.
Hardware Setup
The hardware setup window lists the hardware layers installed on the systems
specified in the network setup. Each layer entry includes the front panel connector ID
names, the layer serial number, the firmware (code) version number, an indication of
applicable ECNs and select configuration details. Use the Query button to populate
the list.
For more information on using TCE to configure hardware, see “Configuring the
Hardware” on page 60. For more information on the configuration options for specific
hardware, see “eDAQlite Hardware” on page 89.
Transducer Channel Setup
Use the transducer channel window to define and modify the transducer configuration
required for the test. This includes defining transducer identification information,
user-programmable settings and calibration methods and parameters. Each
transducer entry includes the transducer ID name, the connector, the transducer
sample rate, the calibration date, the output data type and select configuration details.
Option Description
Edit ID Modify the test identification information shown in the upper window.
Import Import a network node definition from an existing TCE setup file. TCE
also imports all hardware modules, transducer and computed
channels and DataModes associated with the network node.
Add Add a network node to the existing TCE setup file. Specify an IP
address or host name and communication parameters.
Del Delete an existing network node from the TCE setup file. TCE also
deletes all hardware modules, transducer and computed channels and
DataModes associated with the network node.
Edit Modify an existing network node definition.
Data Option Select the desired data file format. For more information on data
format options, see Default data option.
Manage SIE Files Launch the eDAQ
lite
web interface to manage the SIE data files on
the eDAQ
lite
. For more information on managing SIE files, see “SIE
Test Data” on page 181.
Option Description
Query Load the hardware setup from the systems specified as network
nodes. TCE issues a prompt if the queried hardware configuration
differs from the current setup.
Config Display and/or edit the configuration details for the selected hardware
layer. Configuration options are not available for all layers.