B-6
DNW-A75/A75P
525/60
Extended Menu
ITEM-100 series: Operational panel parameter
ITEM Factory setting Current Bank 1 Bank 2 Bank 3 Bank 4
101: SELECTION FOR SEARCH DIAL ENABLE DIAL
102: MAXIMUM SPEED MAX
103: AUDIO SELECTED LINE OUT MANU
104: AUDIO MUTING TIME OFF
105: REFERENCE SYSTEM ALARM ON
106: CAPSTAN LOCK SW
107: REC INHIBIT LAMP FLASHING OFF
108: AUTO EE SELECT S/F/R
109: FORCED EE WHEN TAPE UNTHREAD ON
111: TSO/FEED PLAY DIS
115: PHASE LOCK IN VARIABLE X3 OFF
116: JOG DIAL RESPONSE TYPE1
117: CONTROL PANEL SELECTION SW
118: KEY INHIBIT SWITCH EFFECTIVE AREA
SUB-ITEM 1:REMOTE SELECT DIS
2: MON./INPUT SEL DIS
3: CONTROL PANEL DIS
119: VARIABLE SPEED LIMIT IN OFF
KEY PANEL CONTROL
120: CTL LOCK IN VAR/SHTL OFF
122: AUTO EE WITH ANALOG TAPE DIS
ITEM-200 series: Remote interface parameter
ITEM Factory setting Current Bank 1 Bank 2 Bank 3 Bank 4
201: PARA RUN DIS
ITEM-300 series: Editing parameter
ITEM Factory setting Current Bank 1 Bank 2 Bank 3 Bank 4
301: VAR SPEED RANGE FOR SYNCHRONIZATION _1~+2
302: CAPSTAN RE-LOCKING DIRECTION DECEL
305: SYNC GRADE ACCUR
306: DMC INITIAL SPEED MANU
307: AUTO-DELETION FOR INCONSISTENT DATA MANU
308: SELECTION OF STD/NON-STD FOR AUTO
COMPOSITE VIDEO IN
309: SERVO/AV REFERENCE SEL AUTO1
310: REC INHIBIT ALL