Appendix B Para. Fault List Summary
decelerating
overvoltage threshold
of inverter
Inverter stop decelerating and
maintain the current speed if bus
voltage is more than the setting
value during the deceleration
process, then continue to
decelerate once the voltage drop.
When F245=3, F246~F255 have the following meanings
Current loop Kp (no need to
modify)
Current loop Ki(no need to
modify)
Current loop Kd(no need to
modify)
When F245=4, F246~F255 have the following meanings
Rated current of
inverter current sensor
Set the max power output,
generally do not need to change
When F245=5, F246~F255 have the following meanings
Stator resistor of asynchronous
motor
Rotor resistor of asynchronous
motor
Stator inductor of asynchronous
motor
Rotor inductor of asynchronous
motor