10-16 ELECTRICAL SYSTEM
Measure the relay coil resistance between the terminals using
the multi circuit tester. If the resistance is not within the specified
value, replace the starter relay with a new one.
[ 09900-25008: Multi circuit tester set
Starter relay resistance: 3 – 6 Ω
ΩΩ
Ω
SIDE-STAND/IGNITION INTERLOCK
SYSTEM PARTS INSPECTION
Check the interlock system for proper operation. If the interlock
system does not operate properly, check each component for
damage or abnormalities. If any abnormality is found, replace
the component with a new one.
SIDE-STAND SWITCH
• Remove the maintenance lid. (9-13)
• Remove the left leg shield cover. (9-12)
• Disconnect the side-stand switch coupler and measure the
voltage between Green and Black/White lead wires.
[ 09900-25008: Multi circuit tester set
Tester knob indication: Diode test (=
==
=)
NOTE:
If the tester reads under 1.4 V when the tester probes are not
connected, replace its battery.
SIDE-STAND RELAY
• Remove the leg shield. (9-10)
• Remove the side-stand relay. (10-4)
NOTE:
Wire color of the side-stand relay lead wire are G, O/W, B/W and
Y/B.
ON
(Side-stand up)
OFF
(Side-stand down)
Green
(
+
Probe)
Black/White
(
-
Probe)
0.4 – 0.6 V
More than 1.4 V
(Tester’s battery voltage)