ELECTRICAL SYSTEM 10-21
IGNITION COIL/PLUG CAP RESISTANCE
• Remove the radiator mounting bolt. (10-20)
• Remove the ignition coil/plug cap and disconnect its coupler.
Measure the ignition coil/plug cap resistance in both the primary
and secondary windings. If the resistance is not within the stan-
dard range, replace the ignition coil/plug cap with a new one.
[ 09900-25008: Multi circuit tester set
U Tester knob indication: Resistance (Ω
ΩΩ
Ω)
Ignition coil/plug cap resistance
Primary : 0.8 – 2.5 Ω
ΩΩ
Ω (Terminal – Terminal)
Secondary: 8 – 18 kΩ
ΩΩ
Ω (Plug cap – Terminal)
• Install the ignition coil/plug cap.
CKP SENSOR PEAK VOLTAGE
• Remove the front panel. (9-8)
• Disconnect the wire harness coupler
1 at the ECM.
Measure the CKP sensor peak voltage in the following proce-
dure.
• Connect the multi circuit tester with the peak volt adaptor as
follows.
+ Probe: White lead wire
- Probe: White/Green lead wire
[ 09900-25008: Multi circuit tester set
Before using the multi circuit tester and peak volt
adaptor, be sure to refer to the appropriate instruction
manual.