5: Function Reference
'D' PLL Synthesizer Alarm Disabled
2 =
'D' LPN PLL Alarm Disabled
'E' LPN PLL Alarm Enabled
3 =
'E' GPS Alarm Enabled
'D' GPS Alarm Disabled
4 =
'D' not used
5 =
'D' IRIG Alarm Disabled
'E' IRIG Alarm Enabled
6 =
'D' not used
7 =
'D' not used
8 =
'D' not used
9 =
'D' not used
A =
'E' DAC Alarm Enabled
'D' DACAlarm Disabled
B =
'E' First time lock Alarm Enabled
'D' Firsttime lock Alarm Disabled
C =
'E' Time error Alarm Enabled
'D' Timeerror Alarm Disabled
D =
'E' Time out Alarm Enabled
'D' Timeout Alarm Disabled
E =
'D' NTPAlarm Disabled (Default if NTP Option not enabled)
'E' NTPAlarm Enabled
Query or set Time Error Threshold using the THRESHOLD command. To query the Time
Error Threshold setting, enter:
F73<SP>THRESHOLD<CR><LF>
The XL-GPS responds:
F73<SP>THRESHOLD<SP><nanoseconds><SP>ns<CR><LF>
where <nanoseconds> is the time error threshold in nanoseconds, between 0 and 9999.
To set Time Error Threshold, enter a string the following format:
Page 102 of 221 .................................098-00116-000 Rev. A

Table of Contents

Other manuals for Symmetricom XL-GPS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom XL-GPS and is the answer not in the manual?

Symmetricom XL-GPS Specifications

General IconGeneral
BrandSymmetricom
ModelXL-GPS
CategoryReceiver
LanguageEnglish

Related product manuals