Configuration of sensor using service adapter
/ Vertical menu description / Settings - Output message
DUT-E fuel level sensors. Operation manual. Version 8.1
© Technoton, 2020 75
3.10.6 Settings Output message
One of the following output value types available for DUT-E 232/485
(see figure 51)
:
fuel level in standard (normalized) units (0...1000);
fuel level in millimeters (mm), 0.1 mm step;
fuel volume in liters (L), 0.1 l step;
fuel volume in percentage (%), 0.4 % step.
Figure 51 Selection of output value type for DUT-E 232/485