EasyManua.ls Logo

Technoton DUT-E AF - Page 82

Technoton DUT-E AF
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration of sensor using service adapter / Vertical menu description / Diagnostics
DUT-E fuel level sensors. Operation manual. Version 8.1
© Technoton, 2020 82
Table 17 Malfunction codes
Malfunction code
Transcript of the malfunction
code
Possible solution
Firmware
version up
to 2.9
Firmware
version 2.9
and higher
255
128 (-128)*
Calibration error
Check if the measuring
probe actual size value is
inserted correctly and (or)
recalibrate the sensor**
254
129 (-127)*
253
130 (-126)*
Short circuit in measuring
probe tubes
Wash the measuring probe
tubes with clean fuel, clean
fuel tank of mud and water
252
131 (-125)*
Calibration error
Check if the measuring
probe actual size value is
inserted correctly and (or)
recalibrate the sensor**
251
132 (-124)*
Hardware failure
Contact your supplier
250
133 (-123)*
Calibration error
Check if the measuring
probe actual size value is
inserted correctly and (or)
recalibrate the sensor**
134 (-122)*
* Different malfunction code display.
** Fuel tank calibration table should be recompiled and recorded all over again into sensor
internal memory.