OPERATIONDATA APPENDIX SETTINGSTOOLS CONSOLE
Radion 8140 Automatic Sprayer Control
INTRODUCTION
SETTINGS MENU STRUCTURE
| | | |
Job Parameters Machine OEM Diagnostics
Application Rate Number Filling Sensor Presence Test Inputs
Application Rate Actual Content Flow Sensor Implement Wheel Sensor
Tip Type *Full Tank Liquid Pressure Sensor Tractor Wheel Sensor
Idle Pressure Density Type Fill Flow Sensor Supply Voltage
Density Factor Tank sensor Flow Sensor
Desired Content Implement Parameters Fill Flow Sensor
Implement Speed Sensor Automatic Filling Number of Sections Liquid Pressure Sensor
Calibration Number Operation Circulation Tank Level Sensor
Automatic Calibration Section Conguration Display Rate Smoothing Remote Master Signal
*Flow Sensor Application Rate Step Section Number Valve Setup Master Switch
Calibration Number Speed Source Number of Tips Regulation Valve Type Section Switches
Low Flow Limit Simulate Speed Copy Section Section Valve Type Test Outputs
High Flow Limit Minimum Speed Section Width Section Valve Behavior Liquid Valve PWM Duty Cycle
Automatic Calibration Implement Parameters
Tip Preset Setup Tank Setup Master Valve
*Liquid Pressure Sensor
Calibrations Tip Preset Maximum tank content Fill Valve
No pressure Alarms Tip Series Minimum Tank Content Section Number
No Pressure Calibration Minimum Tank Content Tip Capacity Automatic Filling Section Valve State
Maximum Pressure Flow/Pressure Cross Check Factory Settings Automatic Filling Offset All Sections Off
Maximum Pressure Section Output Low Low Pressure Limit Regulation Details Test BoomPilot
Reference Pressure High Pressure Limit Minimum Regulation Pressure Connection
Automatic Calibration Reference Flow Maximum Regulation Pressure Mode
*Fill Flow Sensor Reference Pressure Regulation Valve Time Section Input
Calibration Number Regulation Parameters Minimum Regulation Voltage Alarm Log
Automatic Calibration Course Value Calibration Regulation Deadband Save Alarm Log
*Tank Level Sensor Fine Value Calibration Regulation Valve Capacity
Empty Tank Tip Spacing Regulation Start Delay
Automatic Calibration Regulation Mode Manual Regulation Speed
Minimum Tank Level Restrictor Plate Flow
Minimal Tank Level Default Valve Position
Automatic Calibration Clear Totals
Maximum Tank Level Area Counter
Maximum Tank Level Volume Counter
Automatic Calibration Time Counter
Tank Shape Clear All Total Counters
Maximum Tank Level Import/Export Calibrations
Start Calibration
Import/Export Calibrations
OEM menu is password protected.
*Menu settings directly related to fitted OEM equipment.