38
INTRODUCTION
www.teejet.com
OPERATION DATA APPENDIXTOOLSCONSOLE
Radion 8140 Automatic Sprayer Control
SETTINGS
Tank Setup
Tank Setup establishes the maximum and minimum tank content, Automatic Flling mode and Automatic Filling Offset value.
Options established here affect the following settings:
►Settings->Machine->Filling->Full Tank
►Settings->Machine->Calibrations->Tank Sensor
SETTINGS MENU STRUCTURE
| | | |
Job Parameters Machine OEM Diagnostics
Sensor Presence
Implement Parameters
Valve Setup
Tank Setup
Maximum tank content
Minimum Tank Content
Automatic Filling
Automatic Filling Offset
Regulation Details
Clear Totals
Import/Export Calibrations
1. From the Home screen, press the SETTINGS button .
2. Press OEM .
3. Press Tank Setup .
4. Press setting value to adjust settings as needed:
◄Maximum Tank Content
◄Minimum Tank Content
◄Automatic Filling
◄Automatic Filling Offset
5. Press RETURN arrow to return to the OEM screen.
Figure 3-43: Tank Setup Screen
Maximum Tank Content
Maximum Tank Content establishes the maximum possible tank
volume is entered. Range is 0 to 65,000 litres.
Minimum Tank Content
Minimum Tank Content establishes the minimum tank volume
agitation should automatically be shut off. Range is 0 to 1,000 litres.
Automatic Filling
Automatic Filling sets automatic lling mode.
Automatic Filling Offset
Automatic Filling Offset establishes the volume that will continue to
run into the tank after the ll valve has started shutting. Range is
0 to 500 litres.