EasyManua.ls Logo

Tektronix 453 - Page 78

Tektronix 453
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
@
~
I
'-"
Set
A TIME/DIV switch
to
.5
ms. Check
for
about
five
complete
cycles/10
divi-
sions
Set
the
A TIME/DIV switch
to
5 ms
and
the
MAG switch
to
X
10.
Check for
about
five
complete
cycles/
1 0
divisions
Yes
Set
MAG switch to OFF, HORIZ
DISPLAY
switch to A INTEN DURING B
and
the
A SWEEP MODE switch to B
STARTS
AFTER
DELAY
TIME. Pull
the
DELA
YEO
SWEEP
knob'
and
set
it to
.5
ms. Check
for
an
intensified
portion
on
the
display
Yes
No
No
Check if A
VARIABLE
TIME/DIV I No
control
is
set
to
CAL
Return A
VARIABLE
control
to
N
CAL
and
check
for
about
five - -
.!
- 1
complete
cycles/
10
divisions
I
Yes Yes :
Check
Horizontal
Amplifier circuit
Check B
unblanking
gate
at
Pin I N
AS
on B
Sweep
board
(about
0.3
°
volts
peak
to
peak)
Yes
I
r------J
Check
for
a
one-kilohertz
square-
wave
at
the
1 kHz
CAL
connector
with
test
oscilloscope
Yes
Check A
Sweep
Generalor
circuit
and
Horizontal
Amplifier
circuit
Check B
Sweep
Generator
circuit
No
------
Check
combined
unblanking
TP1047
on
Z
Axis
board.
gate
at
Waveform•
No
should
show
an
additional
positive
step
during
B
sweep
time
to
intensify
portion
of
trace
Yes
Readjust
INTENSITY control
fied
portion
is
visible
Yes
so
intensi-
I
I
I
I
I
I
_N2_1_
__
- - - - -
-~e~k-Z
A~A;;;;ITTi~;
clr~Utt)
Rotate
the
DELAY-TIME
MULTIPLIER
dial
I-
~t~n~f~~
___
_
throughout
its
range
portion
does
Check B
Sweep
Generator
(Delay-Pickoff
Compara-
tor,
Delay
Multivibrator,
B
Sweep
Reset
Multivibra-
tor
and
B
Sweep
Gate
stages)
Intensified
I
portion
moves
along
trace
not
move
Set
the
HORIZ DISPLAY switch to
DE-
I No
LAYED
SWEEP
IBl
and
position
the
ris-
Check if B TIME/DIV
VARIABLE
I No
control
is
set
to
CAL
ing
portion
of
one
of
the
square
waves
to
the
left
graticule
line.
Check for
about
five
complete
cycles/
10
divisions
Set
the
B SWEEP MODE switch to TRIG-
GERABLE
AFTER
DELAY
TIME
and
set
the
B SOURCE
switch
to
INT, B COU-
PLING switch
to
AC
and
adjust
the
B
LEVEL
control
for
a
stable
display
Stable
I
display
Yes
Stable
display
~
I
- - - - - - - Check B
Trigger
Generator
circuit
cannot
be
obtained
Intensified
Return B TIME/DIV
VARIABLE
con-
No
trol
to
CAL
and
check
for
about
- - ,
five
complete
cycles/
10
divisions
I
I
Yes I
Check B
Sweep
Generator
circuit
Set
the
HORIZ DISPLAY switch to A INTEN
portion
DURING B
and
rotate
the
DELAY-TIME
- - - - - -
-d~;-.;;t-
- -
MULTIPLIER
dial
throughout
its
range
move
Check B
Trigger
Generator
Cir-
cuit
and
Delay
Pickoff
Comparator
stage
Check
Calibrator
circuit
Apparent
trouble
may
have
been
due
to
incorrect
Intensified
portion
'jumps'
between
square
waves
in
display
control
settings.
For a
trouble
not
covered
by
this
Fig.
4-3.
Troubleshooting
chart
for Type
453.
chart,
use
the
troubleshooting
methods
in
steps
6-8
of
the
Troubleshooting
Techniques
f
:;·
-
CD
:::J
a
:::J
"
l
,,
CD
~
""
w
......
~
""
w

Table of Contents