EasyManua.ls Logo

Texas Instruments C2000

Texas Instruments C2000
342 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ePWM
C2000 Microcontroller Workshop - Control Peripherals 7 - 33
ePWM Trip-Zone Enable Interrupt
Register
EPwmxRegs.TZEINT
OST CBC
reserved
15 - 7 02 1
reserved
Cycle-by-Cycle
Interrupt Enable
0 = disable
1 = enable
One-Shot
Interrupt Enable
0 = disable
1 = enable
DCBEVT2 DCBEVT1 DCAEVT2 DCAEVT1
Digital Compare
Output B Event 2/1
Interrupt Enable
0 = disable
1 = enable
3456
Digital Compare
Output A Event 2/1
Interrupt Enable
0 = disable
1 = enable
ePWM Event-Trigger Sub-Module
ePWM Event-Trigger Sub-Module
16-Bit
Time-Base
Counter
Compare
Logic
Action
Qualifier
Dead
Band
PWM
Chopper
Trip
Zone
Shadowed
Compare
Register
Shadowed
Period
Register
Clock
Prescaler
Shadowed
Compare
Register
EPWMxA
EPWMxB
SYSCLKOUT
TZy
EPWMxSYNCI EPWMxSYNCO
TBCLK
Digital
Compare
TZ1-TZ3
COMPxOUT
The event-trigger sub-module is used to provide a triggering signal for interrupts and the start of
conversion for the ADC.

Table of Contents

Other manuals for Texas Instruments C2000

Related product manuals