Natrix IOM
Alignment
Align the charge and discharge ends level and straight in accordance with the center line
reference previously marked on the floor.
The reference points are the surfaces of the guide.
Use a levelling instrument to ensure proper level alignment.
To align for straightness use the appropriate tools.
Anchor unit to the floor or steel structure with the appropriate mounting hardware.
Revision Date: 12/10/2014 Page 37 of 111