Section 3 – SR-2 Software Description
OptiSet Reset
OptiSet features may be reset to default settings
several different ways. These should be considered
when changing OptiSet settings, to be certain that all
ranges are set as desired.
• If any OptiSet features have been previously
set, an OptiSet Reset is provided at the
beginning of the OptiSet menu to return all
settings to the default values. If this OptiSet
Reset feature is used, all OptiSet settings
are returned to factory defaults.
• If any of the four OptiSet global features
(Temperature, Setpoint Low Limit, Setpoint
High Limit and Fresh Frozen Range) are
changed, all OptiSet settings are also
returned to default settings.
• Ranges are programmed from the coldest
range to the warmest range. If ranges have
been programmed and any range is
subsequently changed, the range that was
changed and all warmer ranges are reset to
defaults.
3-25
31 January 2005