153
28. RECORDING DATA - TOPO MENU -
3. Set the following data items.
(1) Instrument station coordinates
(2) Point name
(3) Instrument height
(4) Code
(5) Operator
(6) Date (Display only)
(7) Time (Display only)
(8) Weather
(9) Wind
(10) Temperature
(11) Air pressure
(12) Atmospheric correction factor
Select [LOAD] to recall and use the registered coordinates.
"13.1 Entering Instrument Station Data and Azimuth
Angle PROCEDURE Reading in Registered
Coordinate Data".
When inputting code, [ADD], [LIST] and [SRCH] are
displayed.
Press [ADD] to save input codes in memory.
Press [LIST] to display saved codes in reverse
chronological order.
Press [SRCH] to search for a saved code.
For reviewing and saving codes in Data mode, see
"30.3 Registering/Deleting Codes" and
"30.4 Reviewing Codes"
To set the atmospheric correction factor to 0 ppm, press
[0ppm]. The temperature and air pressure are set to the
default setting.
4. Check the input data, then press [OK].
5. Press {ESC} to restore <TOPO>.
Maximum point name size: 14 (alphanumeric)
Input range of instrument height: -9999.999 to 9999.999 (m)
Maximum code/operator size: 16 (alphanumeric)
Weather selection: Fine, Cloudy, Light rain, Rain, Snow
Wind selection: Calm, Gentle, Light, Strong, Very strong
Temperature range: -35 to 60 (°C) (in 1°C step)/-31 to 140 (°F) (in 1°F step)
Air pressure range: 500 to 1400 (hPa) (in 1hPa step)/375 to 1050 (mmHg)
(in 1mmHg step)/14.8 to 41.3 (inchHg) (in 0.1inchHg step)
Atmospheric correction factor range (ppm): -499 to 499
OKLOAD
HI
PT
ADD
LIST SRCH
CD
P

Table of Contents

Other manuals for Topcon GM-100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon GM-100 Series and is the answer not in the manual?

Topcon GM-100 Series Specifications

General IconGeneral
BrandTopcon
ModelGM-100 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals