119
25. ROUTE SURVEYING
The coordinates of the center peg and width pegs for a straight line can be found from the coordinates of the
reference point and IP point.
It is then possible to proceed with the setting-out of the center peg and width pegs.
PROCEDURE
1. In the second page of the OBS mode screen, press
[MENU], then select "Road".
2. Select "Line" to enter the Straight Line menu.
3. Input the coordinates of the reference point, then press
[OK].
Press [LOAD] to read in the already registered coordinate
data and set as the coordinates of the reference point.
"13.1 Entering Instrument Station Data and Azimuth
Angle PROCEDURE Reading in Registered
Coordinate Data"
The reference point coordinates can be stored as the
coordinates for a known point in the current job by pressing
[REC].
"30.1 Registering/Deleting Known Point Data"
25.2 Straight Line Calculation
P2
P1
Offset
Route origin
Q
QL
QR
BL
AZ
BL
Reference point (P1)
IP point (P2)
Follow-up distance (DL)
Route width (BL)
Target point (Q)
Width peg (QR, QL)
O c c . O r i e n .
R o a d
L i n e
C i r c . C u r v e
S p i r a l
P a r a b o l a
N p :
E p :
L i n e / B P
1 0 0 . 0 0 0
O K
1 0 0 . 0 0 0
LOAD REC

Table of Contents

Other manuals for Topcon GM-100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon GM-100 Series and is the answer not in the manual?

Topcon GM-100 Series Specifications

General IconGeneral
BrandTopcon
ModelGM-100 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals