20. OFFSET MEASUREMENT
6. Sight the right circumscription point (P3) and press [OK].
7. The coordinates of the target point (the center of the column
P0) are displayed. Press [REC] to record the calculation
result.
Press [OK] in the recording screen to return to <Offset>.
Press [YES] to return to <Offset> without recording the
calculation result.
Press [NO] to return to step 3.