Setup and Survey
Topcon HiPer Lite and HiPer Lite+ Operator’s Manual
3-12
8. Click the Positioning tab and set the Elevation mask
parameter to 15 (Figure 3-7), then click Apply.
Figure 3-7. Receiver Configuration – Positioning
9. Select the Base tab, set the following parameters
(Figure 3-8 on page 3-13), and click Apply:
• GPS/GLO at one time – enable
• Antenna position – enter Lat, Lon, and Alt values. Do
one of the following:
–If known, type in the values.
–Enable Averaged and enter the Averaged Span in
seconds, then click Apply. Click ToolsReset
receiver and wait until the specified interval (span)
completes. Examine the Base coordinates on the Base
tab, they should correspond to the coordinates obtained
from the average. Click Refresh if the coordinates are
zeros.
–Click Get from receiver.