Pass
Ifreprogrammingthemachinewassuccessful,gotoReturningtheMachinetoService(page22)
andfollowthestepslisted.
Fail
Ifbothattemptstoreprogramthemachineareunsuccessful,gotoStep3.
Step3:Inspectthewiringforcuttingreelmotor1.
1.GotoPreparingforTroubleshootingand/orT esting(page22)andfollowthestepslisted.
2.Unplugthe48Vdcbatterydisconnecttopreventunexpectedcuttingunitoperation.RefertoConnecting
andDisconnectingthe48VdcBatterySystem(page19).
3.RefertoFigure98tolocatecuttingreelmotor1.
g032972
Figure98
1.Cuttingunit1,whichincludescuttingreelmotor14.Cuttingunit4,whichincludescuttingreelmotor4
2.Cuttingunit2,whichincludescuttingreelmotor25.Cuttingunit5,whichincludescuttingreelmotor5
3.Cuttingunit3,whichincludescuttingreelmotor3
4.Followthecuttingreelmotorcablefromcuttingreelmotor1totheconnectorplatemountedonthe
tractionunit.
Note:The2cuttingreelmotorcableconnectorsaresecuredwithclipstotheconnectorplate.The2
mainharnessconnectorsarenotsecuredtotheconnectorplate.
5.DisconnectmainharnessconnectorsP46andP47fromthecuttingreelmotorcableconnectors.
6.Inspectthe2cuttingreelmotorcableconnectorsandthe2mainharnessconnectorsfordamage,
corrosion,debris,andproperalignmentofthepinsinsidetheconnectors.
Pass
Thewiringinspectionpassed.GotoStep4.
Fail
Oneormoreoftheinspectionchecksfailed.Repairorreplacethewornordamagedparts.Goto
ReturningtheMachinetoService(page22)andfollowthestepslisted.
Step4:TesttheCANbuswiringinmainharnessconnectorP46.
Useamultimetertotesttheresistancebetweenthefollowingpairoflocations:
163