E6582062
5-37 5. [Fundamental operation] How to use parameters
3
4
5
9
Important
Use this parameter with the motor connected.
When the inverter is used with a load that fluctuates considerably, it may fail to adjust the
acceleration or deceleration time in time, and therefore may be tripped.
When using the optional braking resistor or braking unit, do not set <AU1: Automatic Acc/Dec>
to "1". Otherwise, braking resistor overload may occur during deceleration.
Memo
When the acceleration/deceleration time is automatically set, the acceleration/deceleration time
is always changed according to the load. For machinery that requires constant acceleration/
deceleration time, accelerate or decelerate with the setting time of <ACC: Acceleration time 1>
and <dEC: Deceleration time 1> instead of using this function. For details, refer to [5. 2. 4].

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m

Related product manuals