6-141 6. [Advanced] How to use parameters
3
4
6
9
6. 30. 15 Brake answer waiting time setting
<F630: Brake answer wait time>
■ Function
This parameter can set the waiting time for the brake answer (reply) from the system. Input brake
answer to the input terminal with "130: Brake answerback" is assigned.
After the operation start, when there is no answer after elapse of the setting time, the inverter trips.
The trip display is "E-11".
■ Parameter setting
Title Parameter name Adjustment range Unit Default setting
F630 Brake answer wait time 0.0: Disabled
0.1 - 10.0
s0.0
Reference
• How to operate the operation panel -> Refer to [3. 1. 1].
• How to switch display mode on the operation panel -> Refer to [3. 1. 2].
• Procedure to change parameter setting -> Refer to [4. 2. 3]
• This function is used with "brake function".
About "brake function", refer to "E6582104".
0.0HzSTOP
14:00
F630 : Brake answer wait time
Min: 0.0 Max: 10.0
X1000 X100 X10 X1
S
0.0