E6582062
6-141 6. [Advanced] How to use parameters
3
4
6
9
6. 30. 15 Brake answer waiting time setting
<F630: Brake answer wait time>
Function
This parameter can set the waiting time for the brake answer (reply) from the system. Input brake
answer to the input terminal with "130: Brake answerback" is assigned.
After the operation start, when there is no answer after elapse of the setting time, the inverter trips.
The trip display is "E-11".
Parameter setting
Title Parameter name Adjustment range Unit Default setting
F630 Brake answer wait time 0.0: Disabled
0.1 - 10.0
s0.0
Reference
How to operate the operation panel -> Refer to [3. 1. 1].
How to switch display mode on the operation panel -> Refer to [3. 1. 2].
Procedure to change parameter setting -> Refer to [4. 2. 3]
This function is used with "brake function".
About "brake function", refer to "E6582104".
0.0HzSTOP
14:00
F630 : Brake answer wait time
Min: 0.0 Max: 10.0
X1000 X100 X10 X1
S
0.0

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m