6-177 6. [Advanced] How to use parameters
3
4
6
9
6. 34. 11 Selecting panel display at power on
<F790: Panel display at power on>
<F791: 1st and 2nd characters of F790>
<F792: 3rd and 4th characters of F790>
<F793: 5th and 6th characters of F790>
<F794: 7th and 8th characters of F790>
<F795: 9th and 10th characters of F790>
<F796: 11th and 12th characters of F790>
<F797: 13th and 14th characters of F790>
<F798: 15th and 16th characters of F790>
Function
These parameters allow you to change the characters on panel display at power on.
By default setting, "HELLO" is displayed, but the word changes depending on the language
selection. (The word equivalent of "Hello" for each language is displayed.)
Parameter setting
Guideline for the setting
To display characters other than "HELLO", set <F790> to "1" and set the characters Changing
variation steps of panel display displayed with <F791> to <F798>.
Refer to "ASCII LED" of RS485 Communication Function Instruction Manual (E6582143) for setting
of characters and set by hex number.
Title Parameter name Adjustment range Default setting
F790 Panel display at power
on
0: HELLO (depending on language selection)
1: F791 - F798
2, 3: -
0
F791 1st and 2nd characters of
F790
0-FFFF 2d2d
F792 3rd and 4th characters of
F790
0-FFFF 2d2d
F793 5th and 6th characters of
F790
0-FFFF 2d2d
F794 7th and 8th characters of
F790
0-FFFF 2d2d
F795 9th and 10th characters
of F790
0-FFFF 2d2d
F796 11th and 12th characters
of F790
0-FFFF 2d2d
F797 13th and 14th characters
of F790
0-FFFF 2d2d
F798 15th and 16th characters
of F790
0-FFFF 2d2d
1: F791-F798
0.0HzSTOP
14:16
0: HELLO (depend on a language)
F790 : Panel display at power on

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m