E6582062
8-7 8. Monitoring operation status
3
4
8
9
Settings for <F711: Monitor mode 1 display> to <F718: Monitor mode 8 display>
Setting
value
Function name Display unit
Setting
value
Function name
Display
unit
0 Output frequency 0.1 Hz 71
Motor speed (estimated
value, Max. 32700 min
-1
)
min
-1
1 Frequency command value 0.1 Hz 72
Communication option
Receiving counter
1
2 Output current
1%/<F701>
setting
*1
73
Communication option
Abnormal counter
1
3 Input voltage (DC detection)
1%/<F701>
setting
*1
76
Terminal S4/S5 pulse train
input value
0.10%
4 Output voltage
1%/<F701>
setting
*1
77 My function COUNT1 1
5 Stator frequency 0.1 Hz 78 My function COUNT2 1
6
Speed feedback frequency
(real time)
0.1 Hz 79
Dancer control PID result
frequency
0.1 Hz
7
Speed feedback frequency
(1-second filter)
0.1 Hz 80
Embedded Ethernet
Transmission counter
1
8 Torque
1%
*1
81
Embedded Ethernet
Receiving counter
1
9 Torque command
1%
*1
82
Embedded Ethernet
Abnormal counter
1
10
Output frequency during run.
Hz/free unit
83 Connected option number 1
Frequency command value
during stop.
84 My function COUNT3 1
11 Torque current
1%
*1
85 My function COUNT4 1
12 Exciting current 1% 86 My function COUNT5 1
13 PID feedback value 0.1 Hz 90 Cumulative power ON time 100 hours
14
Motor overload factor (OL2
data)
1% 91
Cumulative cooling fan run
time
100 hours
15
Inverter overload factor (OL1
data)
1% 92 Cumulative run time 100 hours
16
Braking resistor overload
factor (OLr data)
1% 93 Cumulative overcurrent time 100 hours
17
Braking resistor load factor
(%ED)
1% 95 Pump 0 run time 100 hours
18 Input power
0.1 kW
*1
96 Pump 1 run time 100 hours
19 Output power
0.1 kW
*1
97 Pump 2 run time 100 hours
20 Input cumulative power
<F749>
setting
98 Pump 3 run time 100 hours
21 Output cumulative power
<F749>
setting
99 Pump 4 run time 100 hours