E6582062
11-45 11. Table of parameters
1
3
9
10
11
F875 0875 Block read data 1 0: Disabled
1: FD01 (Status
information)
2: FD00 (Output
frequency)
3: FD03 (Output current)
4: FD05 (Output
voltage)
5: FC91 (Alarm
information)
6: FD22 (PID feedback
value)
7: FD06 (Input terminal
monitor)
8: FD07 (Output
terminal monitor)
9: FE35 (Terminal RR
monitor)
10: FE36 (Terminal RX
monitor)
11: FE37 (Terminal II
monitor)
12: FD04 (Input voltage
(DC detection))
13: FD16 (Speed
feedback frequency)
14: FD18 (Torque)
15: FE60 (My function
output monitor 1)
16: FE61 (My function
output monitor 2)
17: FE62 (My function
output monitor 3)
18: FE63 (My function
output monitor 4)
19: 0880 (Free
memorandum)
20: FD90 (Motor speed)
21: FD29 (Input power)
22: FD30 (Output
power)
23: FC90 (Trip
information)
--0Y
[6. 38. 1]
F876 0876 Block read data 2 - - 0 Y
F877 0877 Block read data 3 - - 0 Y
F878 0878 Block read data 4 - - 0 Y
F879 0879 Block read data 5 - - 0 Y
F880 0880 Free memorandum 0-65535 - 1/1 0 Y [6. 38. 3]
F896 0896
Parameter for
manufacturer
------
F897 0897 Parameter writing
0: Storage to memory
device
1: Storage to memory
device except by
communication
--0Y -
F898 0898 Trip reset
0: Clear trip by request
from communication
option. Reset by
request except from
communication
option.
1: Reset
2: Trip clear
3 - 5: -
--0N -
Title
Communication
No.
Parameter name Adjustment range Unit
Minimum
setting unit
(Panel/
Communication)
Default
setting
Write
during
running
*6
User
setting
Reference

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m