E6582062
11. Table of parameters 11-46
1
9
11
F899 0899
Communication
option reset
0: -
1: Reset option and
inverter
- - 0 N [6. 38. 1]
F907 0907
PM regenerative
over-flux upper limit
0 - 150 % 50 N -
F908 0908 PM no load current 0 - 100 % 0 N -
F909 0909
PM step-out
detection frequency
rate
0 - 100 % 0 N -
F910 0910
PM step-out
detection current
level
1 - 150 % 100 N
[6. 39]
F911 0911
PM step-out
detection time
0.00: Disabled
0.01 - 2.55
s0.00N
F912 0912
PM q-axis
inductance
0.01 - 650.0 mH 10.00 N
[6. 23. 2]
F913 0913
PM d-axis
inductance
0.01 - 650.0 mH 10.00 N
F914 0914
Parameter for
manufacturer
------
F915 0915 PM control method
0: Method 0
1: Method 1
2: Method 2
3: Method 3
4: Method 4
- - 3 N [6. 23. 2]
F916 0916 PM starting current 0 - 100 % 25 N -
F917 0917
IPM maximum
torque control
0: Disabled
1: Enabled
-0Y-
F918 0918
IPM current phase
adjustment
-45.0 to +45.0 °C 0.0 Y -
F919 0919
Parameter for
manufacturer
------
F920 0920
Parameter for
manufacturer
------
F921 0921
SPM initial position
estimation current
10 - 150 % 100 N -
F922 0922
PM HF control
speed estimation
response
5 - 80 Hz 15 N -
F923 0923
PM control
switching speed
5 - 100 % 25 N -
F924 0924
PM speed
estimation filter
cutoff frequency
1 - 80 Hz 30 N -
F925 0925
PM HF control
speed estimation
stabilization
coefficient
0.50 - 2.50 1.00 N -
F926 0926
PM HF control
harmonic
frequency
100 - 1000 Hz 500 N -
Title
Communication
No.
Parameter name Adjustment range Unit
Minimum
setting unit
(Panel/
Communication)
Default
setting
Write
during
running
*6
User
setting
Reference