E6582062
13-11 13. Trip information and measures
I
II
III
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
CHn Setting for China Setting for China is selected in the setup
menu.
-
CLr Reset command
acceptable
The following was operated after trip is
occurring.
1) Pressed [STOP] key once.
2) Set the reset terminal ON.
(During trip resetting operation)
Reset is performed with the following
operation.
1) Press [STOP] key again.
2) Set the reset terminal OFF.
db During DC braking DC braking in progress. -
dbOn During motor shaft
fixing
Motor shaft fixing in progress. A message indicates the motor fixing control
in progress. When standby is turned OFF, the
control stops.
E1 Panel display one
digit overflow
The display digit on the operation panel
overflowed by one digit.
-
E2 Panel display two
digits overflow
The display digit on the operation panel
overflowed by two digits.
-
E3 Panel display three
digits overflow
The display digit on the operation panel
overflowed by three digits.
-
EASy Easy mode Switched to [Easy mode]. -
End Last of data The last data item in <History function>. -
EOFF Emergency off
command
acceptable
When a run command is other than the
operation panel, [STOP/RESET] key was
pressed once.
To apply emergency off, press [STOP] key
again.
If emergency off does not occur, press other
keys.
Err1 Frequency point
setting error
The setting on point 1 and point 2 of the
frequency command is close.
Set apart point 1 and point 2 of the frequency
command.
EU Setting for Europe Setting for Europe is selected in the setup
menu.
-
FAIL Password failure Entered number in <F739: Password
verification> does not match <F738:
Password setting>.
-
FIrE During Fire speed
run/Forced run
Fire speed run/Forced run is in progress.
("FIrE" and the output frequency are
alternately displayed)
A message indicates fire speed run/forced
run in progress. It stops when turning the
power OFF.
FJOG Fwd JOG Forward jog run in progress. -
HEAd Head of data The first data item in <History function>. -
HI Upper limit of
setting value
The upper limit of the setting value. -
Init During Initializing • Set <tyP: Default setting> = "3" or "13" and
initialization is in progress.
• Region setting in progress with the setup
menu.
No problem if the display shows "0.0" after
several seconds.
JP Setting for Japan Setting for Japan is selected in the setup
menu.
-
LO Lower limit of
setting value
The lower limit of the setting value. -
LStP During run sleep Run sleep in progress. -
n--- No detailed
information of past
trip
While "nErr" and a value are alternately
displayed, [OK] key is pressed and detailed
information are read.
Normal display.
Message
display
English Description Remarks