EasyManua.ls Logo

VHF E5 - Emergency Working Chamber Door Opening

VHF E5
105 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.3 Emergency opening of the w ork-
ing chamber door
CAUTION
Cutting injuries when touching a
rotating tool
If a power failure or a machine malfunction occurs
during machining, the spindle including the inserted
tool keeps rotating. If you touch the rotating tool, you
will suffer from cutting injuries.
Wait until the spindle has stopped rotating before
performing an emergency opening.
Due to the safety interlock you can only open the
working chamber door when the machine is supplied
with power. In the event of a prolonged power failure,
use the emergency release to access the working
chamber.
The emergency release is located on the rear of the
machine.
FIG. 281
1. DANGER! Switch off the machine at the main
power switch.
2. Disconnect the machine from the eletrical source.
3. Remove the protective cap from the emergency
release opening.
4. Pull the ring up to the stop and hold it in this posi-
tion.
5. Open the working chamber door.
6. Let go of the ring.
7. CAUTION! Wear gloves.
8. Carry out your work in the working chamber.
9. Close the working chamber door.
WARNING! Danger of crushing and cutting
injuries when the working chamber door is
unlocked during operation
10. Check if the working chamber door is actually
locked.
If this is not the case, try once again to lock the
working chamber door.
11. If the working chamber door cannot be locked,
secure the machine against being switched on
again. Contact customer service.
12. Close the opening for the emergency release again
with the protective cap.
FIG. 282
FIG. 283
FIG. 284
Troubleshooting
EN 99
Original Operating Instructions: E5
Version: 4/27/2023

Table of Contents