SHB 803 en – Edition 2.4 * 803s311.fm 3-11
Maintenance
Leakage check ( ):
Check for tightness, leaks and chafing: pipes, flexible lines and threaded fittings of the following assemblies and components. Rectify if necessary:
• Visual check
●●
☞Engine, hydraulic system and hydraulic components ●●
☞Cooling circuit ●●
☞Traveling drive ●●
1. Drain engine oil the first time after 50 o/h, then every 250 o/h
2. Replace the engine oil filter the first time after 50 o/h, then every 250 o/h
3. Replace the fuel filter the first time after 50 o/h, then every 500 o/h
4. Replace the hydraulic oil filter insert the first time after 50 o/h, then every 500 o/h
5. Replace the hydraulic oil the first time after 500 o/h, after 1000 o/h the second time, then every 1000 o/h
6. According to the dirt indicator, every 1000 o/h or once a year at the latest. (Replace after 50 o/h when in extensive use in environments with acidic air, such as acid production facilities, steel and aluminum mills, chemical plants and other nonferrous-metal plants)
7. Clean the water ducts every other 1000 o/h servicing
8. Clean and adjust the fuel injection pump every other 1000 o/h servicing
9. Check and adjust injection time every other 1000 o/h servicing
10. Check the first time after 50 o/h, then every 500 o/h
11. Check once a week
12. Check the first time after 50 o/h, then every 500 o/h
3.3 Maintenance plan (overview)
Work description
For servicing and maintenance on the attachment, please refer to the operation and maintenance manual of
the attachment manufacturer.
Maintenance plan/operating hours (o/h)
Maintenance
(once a day)
Every 50 o/h
Every 250 o/h
Every 500 o/h
Every 1000 o/h
once a year
Every 2000 o/h
Customer
Authorized
service center