1.2.1.3 Use external power function
If the cylinder battery is flat, the lock can be
opened or closed using the battery in an
active key. If the key has no battery (= passive
key), the locking authorisations in the passive
key can be read using an active key. This can
then open or close the lock with the inte-
grated battery within a period of 20 seconds.
Prerequisites:
n You have a passive key with locking authorisation.
n You have an active key without locking authorisation.
1. Activate active key (4) by pressing on the button (3)
for 2 seconds.
2. Connect active key (4) with the passive key (1) using
adapter.
ð
The LED display (2) on the active key lights up
yellow during the read process.
The locking authorisations in the passive key (1)
have been read if the LED display (2) lights up
green.
3. Insert active key (1) into the cylinder.
ð
The LED display (3) on the active key (1) lights up
yellow and the cylinder can be operated using the
power in the battery (2) in the active key (1) within
a period of 20 seconds.
The locking authorisation for the cylinder expires
after 20 seconds.
Read passive key
Fig. 8: Read passive key
Operate the cylinder
Fig. 9: Operate the cylinder
Product overview
23.03.2020 blueCompact electronic locking system 21