July 2019
4-44
Xerox® B210 Service Manual
REP 5.1
Initial Release
Repairs - Adjustments
3. Disconnect the Fuser Connectors (2), Figure 1.
a. Connector CON2 from the LVPS PWB.
b. Connector FUSER from the Main PWB.
Figure 1 Fuser Connectors
NOTE: Remember the location of the Screw with the larger head for Fuser replacement.
4. Remove four screws, then remove the Fuser Module routing the harness through t
he
f
rame, Figure 2
.
Figure 2 Fuser Screws (Rear View)
Replacement
Replacement is the reverse of the removal procedure.
NOTE: Tapered plastic screws and round machine screws are used to hold the fuser to the
f
rame. Make sure that the plastic screws go into plastic components and machine screws go
into the metal frame.