Repairs and Adjustments
8. Remove the PMO - dummy base frame, PMO - cam jam remove and MEA unit - cover
front assembly, Figure 1.
Figure 1 Dummy base frame removal
9. Remove the cover bracket motor and PMO lock developer, Figure 2.
Figure 2 Cover bracket motor removal
10. (2218) Remove the IPR - shield SMPS upper, refer to REP 1.7. Disconnect CON52 from
the SMPS - PSP fuser.
11. Disconnect the relevant connectors from the SMPS+HVPS and PBA main (M20F) or the
SMPS, HVPS and PBA main (4118/2218).
1
Remove 5 screws.
2
Remove the PMO -
dummy base frame, then
the cam.
3
Remove the MEA unit - cover
assembly.
1
Remove 1 screw, then
the cover bracket motor.
2
Remove the PMO lock developer.