XT2640OperatingManual 13July2016 Page10of187
VectorScreen‐displaysfundamentalvoltageandcurrentvectorswithuserdefinedcoloring
HistoryScreen–theunitautomaticallymaintainsacontinuoushistoricalrecordingofmeasurementdata–noconfiguration
needed.Anydatafromthisrecordmaybeviewedwithuserdefinedscaling,offsetandcolor,withausercursorforzooming
andobtainingnumericallevels
ScopeViewScreen‐anextremeresolutiondigitalscopetocaptureeventssuchasin‐rushcurrentwithoutinterferingwith
othermeasurements,withausercursorforzoomingandobtainingnumericallevels
CycleViewScreen‐displaysasinglecycleofthevoltageandcurrentperiodicwaveforms,jittersampledovermultiple
cycleswithineachmeasurementperiodgivingtimeresolutiondownto2.6ns–noconfigurationneeded
StandbyPowerScreen–allowsEN50564compliantlowpowermeasurementswithouttheneedforacomputer.
AssessEUTScreen–allowsEN61000‐3‐2and‐12assessmentsofcompliancewithouttheneedforacomputer.
Upto1000unitscanbeconfiguredinasinglemulti‐unitgrouptoprovidetotalefficiencyandpowerlossmeasurementsinthe
mostcomplexofsystemrequirements(requiresoptionMU).
Connectivity‐Ethernet,HighSpeedSerialandUSB(client),or(optional)GPIBcontrolinterfaces
Safety‐CEmarkcertifiedtoEN61010withcertifiedconformancetoCATI,II,IIIandIVmainsmeasurementapplications