XT2640OperatingManual 13July2016 Page147of187
24.4.9.4 SCOPEVIE WCONFIGURATION COMMANDS
COMMAND
KEYWORD
FIELD(s)
FIELD
FORMAT
FIELD
DATA
RANGE
DESCRIPTION
SCOPEINRUSH e NR1 0or1
SetsifperformingascopecapturewilltemporarilyoverridetheARANGEsettingto
HIandtheBANDWIDTHsettingtoUNFILTERED(e=1)ornot(e=0).
TIMEBASE b NR1 0to20
Setsthescopedatacapturetimebaseto5µs(b=0),10µs(b=1),20µs(b=2),50µs
(b=3),100µs(b=4),200µs(b=5),500µs(b=6),1ms(b=7),2ms(b=8),5ms(b=9),
10ms(b=10),20ms(b=11),50ms(b=12),100ms(b=13),200ms(b=14),500ms
(b=15),1s(b=16),2s(b=17),5s(b=18),10s(b=19)or20s(b=20)
TRIGGER
i
NR1 0to7 Configuresscopedatacapturetriggering
TriggerInput(i):
i=0:TriggerusingCH1Vinputsignal
i=1:TriggerusingCH1Ainputsignal
i=2:TriggerusingCH2Vinputsignal
i=3:TriggerusingCH2Ainputsignal
i=4:TriggerusingCH3Vinputsignal
i=5:TriggerusingCH3Ainputsignal
i=6:TriggerusingCH4Vinputsignal
i=7:TriggerusingCH4Ainputsignal
TriggerDetectionMethod(t):
t=0:DCrisingedge
t=1:DCfallingedge
t=2:Rectifiedsignal(risingedge)
t=3:HighFrequency
TriggerPosition(p):
p=0:Triggerisat0%ofthecapturedtimespan
p=1:Triggerisat25%ofthecapturedtimespan
p=2:Triggerisat50%ofthecapturedtimespan
p=3:Triggerisat75%ofthecapturedtimespan
TriggerLevel(l)inVorAunitsasapplicable
t NR1 0to3
p
NR1 0to3
l NR3 Any
24.4.9.5 INTEGRATION CONFIGURATIONCOMMANDS
COMMAND
KEYWORD
FIELD(s)
FIELD
FORMAT
FIELDDATA
RANGE
DESCRIPTION
INTEGAUTO i NR1 0or1
Setsthatintegrationwillbeautomaticallytimed(
i
=1)ormanually
stoppedandstarted(i=0)
INTEGDELAY
d NR1 0to99
Setstheautomaticallytimedintegrationstartdelaytimetoddays,h
hours,mminutesplussseconds.
h NR1 0to99
m NR1 0to99
s
NR1 0to99
INTEGRUN
d NR1 0to99
Setstheautomaticallytimedintegrationruntimetoddays,hhours,m
minutesplussseconds.
h NR1 0to99
m NR1 0to99
s NR1 0to99
24.4.9.6 MOTORMEASUREMENTCONFIGU RATIONCOMMANDS
Thesecommandsonlyhaveaneffectifamotorchannelisinstalled,buttheyarestillvalidifnomotorchannelisinstalled.
COMMAND
KEYWORD
FIELD(s)
FIELD
FORMAT
FIELD
DATA
RANGE
DESCRIPTION
DIR n NR1 0or1
SetsthattheDIRinputistakenasmeaningaforwarddirectionifHI(n=0)or
LO(n=1)atthetimeofthedetectedSPDinputedge.Thisonlyhaseffectfora
SPDsettingof3.
MTRDIGITS n NR1 3to6
SetsthatmotorresultsshallbedisplayedwithndigitsonthePOWERDATA
andCUSTOMscreens.
MTREFFGROUP n NR1 0to3
Setstheefficiencygroup formotorpowertoNone(n=0),IN(n=1),MIDDLE
(n=2)orOUT(n=3)
MTRPERIOD n NR1 0to11
Setsthemeasurementperiodformotormeasurementaccordingtothevalueof
nasfollows‐
0:10msmeasurementperiod
1:30msmeasurementperiod
2:100msmeasurementperiod
3:300msmeasurementperiod
4:1smeasurementperiod
5:3smeasurementperiod
6:10smeasurementperiod
7:30smeasurementperiod
8:100smeasurementperiod
9:MeasurementperiodsynchronouswithVPA1
10:MeasurementperiodsynchronouswithVPA2
11:MeasurementperiodsynchronouswithVPA3

Table of Contents