Fuel prefilter
Fig. 6-17 Fuel prefilter
1 Bleeding screw
2 Fuel feed from fuel tank
3 Fuel supply to pump
4 Fuel transfer pump
5 Electric connection for water level sensor
6 Drain plug
7 Filter element
Empty the water
collection tank
Shut down the engine.
Detach the cable (5).
Attach a hose to the drain plug (6) and feed it into a container.
Release the drain plug (6) and allow the fluid to drain until clear diesel fuel
comes out.
Fit the drain plug (6).
Torque: 1.6 ± 0.3 Nm
Attach the cable (5).
1 2
3
4
5
6
7